Charts on Corrugated Fiberglass Profiles

ePlastics

by

4/10/2018 2:50 pm

Click Here to View Charts on Corrugated Profiles

Profile Guide

Click thumbnail for larger picture! A hard copy of this chart is available to fax to you in case you can not see the photo. Please call one of our industrial salesmen!

 

Span and Loading Table for FRP Corrugated Panel


180 Series Panels

Span & Loading Table
TYPE 2.5" 2.67" R U 4.2" 7.2" 5.33"
ROOFING
10 psf 66" 71" 63" 71" 72" 76" 75"
20 psf 57" 62" 49" 58" 60" 65" 74"
30 psf 47" 54" 34" 44" 48" 54" 72"
40 psf 38" 46" 20" 31" 36" 42" 70"
Siding
10 psf 67" 73" 67" 75" 75" 80" 76"
20 psf 63" 68" 57" 65" 66" 71" 75"
30 psf 59" 62" 46" 55" 58" 63" 73"
40 psf 54" 57" 36" 46" 49" 55" 72"
2.5" 2.67" R U 4.2" 7.2" 5.33"

 

See the dimensional specificatons chart to see what the type looks like!

Typical Corrugated FRP Construction Details

Click on thumbnail to view larger picture! This information can also be mailed to you, please call one of our industrial salesmen!

 

Typical FRP Panel Physical Properties

8 oz./ft. squared Nominal Weight

TYPICAL PHISICAL PROPERTIES 
 
R panel - Chopped Strand Mat Reinforcement ASTM No. 
 
Tensile Strength D638 10,000 PSI
Tensile Modulus D638 SEE NOTE 1
Flexural Strength D790 25,000 PSI
Flexural Modulus D790 SEE NOTE 2
Compressive Strength D695 25,000 PSI
Shearing Strength D732 12,000 PSI
Barcol Hardness D2583 45
Glass Content D2584 22% ± 2%
Water Absorption D570 0.25% @ 72°F/72 hrs.
Specific Gravity D792 1.45
Izod Impact D256 9.0 ft. lbs/in.
Coefficient of Linear Thermal Expansion D696 SEE NOTE 3
Flash Ignition Temperature D1929 730° F
 
R panel - Woven Roving/Chopped strand mat reinforcement ASTM No. 
 
Tensil Strength D638 23,000 PSI
Tensil Modulus D638 SEE NOTE 4
Flexural Strength D790 33,000 PSI
Flexural Modulus D790 SEE NOTE 5
Compression Strength D695 30,000 PSI
Shearing Strength D732 16,000 PSI
Barcol Hardness D2583 45
Glass Content D2584 35% ± 2%
Water Absorption D570 0.25% @ 72°F/72 hrs.
Specific Gravity D792 1.6
Izod Impact D256 14.0 ft. lbs/in.
Flash Ignition Temperature D1929 730° F

Note 1 = 1.6 x 10 to the 6th power (psi)
Note 2 = 1.10 x 10 to the 6th power (psi)
Note 3 = 2.09 x 10 to the neg. 5th power in/in/°F
Note 4 = 1.5 x 10 to the 6th power (psi)
Note 5 = 1.2 x 10 to the 6th power (psi)

 

Typical Light Transmission Values 
 
COLOR 150 Series 180 Series
 
400 Light Green 85% 75%
614 White 65% 55%
718 Clear 94% 93%

Percentages given were obtained using ASTM 1494-60, and are subject to tolerances of ± 5%.